Rate Sensor Setup - Raven Command FLEX II Calibration And Operation Manual

Table of Contents

Advertisement

NCV RESPONSE SENSITIVITY
(Not available in NCV Bypass or On/Off control mode) The NCV response sensitivity controls how sensitive the
system is to changes in pressure, flow, and speed. Decrease sensitivity if system pressure and rate oscillate
slightly. Increase sensitivity if control is unresponsive. Avoid setting sensitivity above 70.
STANDBY MODE
Select the desired Standby Mode and Standby Pressure Offset for when the product switch or pump is on, but the
system is not spraying, to maintain a boom or pump pressure in the system for agitation, recirculation, or to
ensure boom pressure does not drop when spraying resumes.
Boom Pressure. System will maintain a target boom pressure. When in Standard or High Flow NCV Control
modes, the target spray pressure value from the home screen will be used as the standby pressure when not
spraying. When in any other control mode, the minimum pressure will be used as the target boom pressure when
not spraying. Any value entered in for Standby Pressure Offset will add to the target pressure, and the system will
maintain that pressure when not spraying.
NOTE:
For example, if the target spray or minimum pressure is 30 psi, and a 5 psi Standby Pressure Offset is
entered, the boom pressure will be maintained at 35 psi when not spraying.
Pump Pressure. System will maintain a target pump pressure. This option is not available if a pump pressure
sensor is not configured. When in Standard or High Flow NCV Control modes, the target spray pressure value
from the home screen will be used as the standby pressure when not spraying. When in any other control mode,
the minimum pressure will be used as the target pump pressure when not spraying. Any value entered in for
Standby Pressure Offset will add to the target pressure, and the system will maintain that pressure when not
spraying.
NOTE:
For example, if the target spray or minimum pressure is 30 psi, and a 5 psi Standby Pressure Offset is
entered, the pump pressure will be maintained at 35 psi when not spraying.
Pump PWM. System will maintain a target pump PWM% when not spraying. This is the default standby mode
when direct injection or boom recirculation are configured on the system. For best results when spraying resumes,
adjust the pump PWM to be no less than the pump PWM readout when actively spraying.
Hold. System will hold the last control valve position or PWM% when not spraying.

RATE SENSOR SETUP

To adjust rate sensor and tank fill sensor calibration values and units:
UT Menu
RCM - Sprayer Menu
1. Open the UT Menu and select the RCM - Sprayer Menu button.
2. Select the Tools Menu softkey along the right side of the display.
3. Select the System Settings tab along the top of the display.
4. Select the Rate Sensor Setup button on the System Settings page. The following settings and options are
available to help improve applicator efficiency.
System Setup: System Settings Tab
Tools Menu
System
Settings
SYSTEM SETUP
Rate Sensor
Setup
29

Advertisement

Table of Contents
loading

Table of Contents