Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers 016-0171-727 Rev. A 4/2022 E41531 Copyright 2022...
Page 2
Raven systems, or products used as components of systems, which rely upon the reception of these signals or availability of these services. Raven Industries accepts no responsibility for the use of any of these signals or services for other than the stated purpose.
• Do not operate this Raven system or any agricultural equipment while under the influence of alcohol or an illegal substance. • Be alert and aware of surroundings and remain in the operator seat at all times when operating this Raven system.
• Do not connect the power leads to the battery until all system components are mounted and all electrical connections are completed. • Always start the machine before initializing this Raven system to prevent power surges or peak voltage. • To avoid tripping and entanglement hazards, route cables and harnesses away from walkways, steps, grab bars, and other areas used by the operator or service personnel when operating or servicing the equipment.
The word “hose” is used to describe any flexible, fluid carrying components. Use the following guidelines and recommendations when connecting and routing hoses while installing or maintaining this Raven system: • Leave protective caps/covers over hose ends until connecting the end into the hydraulic system to help prevent contaminants from entering the system.
Page 8
• Clean electrical components with pressurized air, aerosol electrical cleaning agent, or low pressure rinse. • Remove visible surface water from electrical components and connections using pressurized air or an aerosol cleaning agent. Allow components to dry thoroughly before reconnecting cables. Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
I NTRODUCTION CHAPTER C H A P T E R 2 Thank you for purchasing the boom recirculation system. This system is designed to allow the equipment operator to prime the boom or agitate chemical in the boom plumbing without spraying chemical on the ground. This system allows the operator to adjust the recirculation flow based upon the spray system or the chemical needs and will automatically disengage when normal application is started or if a chemical injection system is detected.
RECOMMENDATIONS Raven Industries recommends the following best practices before installing or operating the boom recirculation system for the first time, at the start of the season, or when moving the boom recirculation system to another machine: •...
If you have questions about the kit, contact your Raven dealer. FIGURE 1. Case IH 50 Series Patriot Sprayer Boom Recirculation Kit Contents (P/N 117-2005-059 Rev. A) PART #...
Page 12
CHAPTER 2 FIGURE 2. Case IH 50 Series Patriot Sprayer Boom Recirculation Boom Plumbing Kit Contents (P/N 117- 0171-894 Rev. A) PART # DESCRIPTION (BUNDLE HOSE, LEAVE OUTSIDE BOX) BUMBLE BEE NYLON BRAIDED HOSE, 1-1/2" 120' EPDM DOUBLE BRAIDED HOSE, 1-1/4"...
Applied Technology Division web site: https://portal.ravenprecision.com The Raven Service Tool and a laptop PC are required to perform software updates to the ECU. Refer to the Raven Service Tool Operation manual for additional assistance with updating the ECU.
Page 14
CHAPTER 2 Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
I NSTALLATION CHAPTER C H A P T E R 3 OVERVIEW FIGURE 1. 7 Example of the Boom Recirculation Update System 1. Main Tank 5. Drain Valve Added or 2. Main Pump 6. Electric Return Valve Modified Parts 3. Main Flow Meter 7.
4. Once assembly is complete, mount the bracket to the center rack at the rear of the machine using the existing hardware. Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 17
INSTALLATION FIGURE 3. Center Rack Return Bracket Mounting Location 4-Bolt Mount Location Installation: Assemble and Mount the Return and Throttling Valve...
CHAPTER 3 PLUMB THE DRAIN AND TANK RETURN FIGURE 4. Tank and Drain Recirculation Plumbing Diagram From Eductor Drain / Reclaim Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 19
INSTALLATION 1. Mount the M200 x M100 tee to the return mount bracket (P/N 107-0172-764) with two U-bolts, 1/4” washers, and 1/4” lock nuts. 2. Assemble the 1” check valve to the M100 port of the tee as shown in Figure 4 on page 14. NOTE: Pay close attention to the arrow on the check valve to allow flow to return from the boom to the tank.
Page 20
7. Route the 1.25” boom hose from the drain tee back to the electric valve on the center rack by following the product supply hose along the side of the sprayer and onto the center rack. FIGURE 7. Return Hose Routing Return Hose Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
INSTALLATION CENTER BOOM SECTIONS Follow the best practices below for the most optimal installation: • Remove all standard BEFVs and tube end threaded adapters. • Remove sweeping tee feed points and tube end threaded adapters where indicated. • For hose-to-hose barb connections, use two hose clamps that are oriented in opposite tightening directions to secure the hose to the hose barb fitting (only one hose clamp is depicted in figures).
Page 22
1. Assemble the center boom plumbing as shown in Figure 8 on page 18 or Figure 11 on page 20 according to the matching boom width and section configuration. FIGURE 8. Center Boom Plumbing for 5-Section (90’) and 7-Section (120’, 132’, 135’) Boom Configurations To Tank Drain Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 23
INSTALLATION FIGURE 9. Center Boom Section Plumbing Example for 5-Section and 7-Section Boom Hose Routing Over Fold Joint FIGURE 10. Center Boom Section Plumbing Example for 5-Section and 7-Section Boom P-Clamp Hose Here Installation: Center Boom Sections...
Page 24
CHAPTER 3 FIGURE 11. Center Boom Plumbing for 6-Section (90’ and 100’) Boom Configurations To Tank Drain Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
INSTALLATION BOOM PLUMBING Follow the best practices below for the most optimal installation: • Remove all standard BEFVs and tube end threaded adapters. • Remove sweeping tee feed points and tube end threaded adapters where indicated. • For hose-to-hose barb connections, use two hose clamps that are oriented in opposite tightening directions to secure the hose to the hose barb fitting (only one hose clamp is depicted in figures).
CHAPTER 3 BOOM PLUMBING FOR 5-SECTION (90’) FIGURE 12. Inner Boom Plumbing for 5-Section (90’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 27
INSTALLATION FIGURE 13. Outer Boom and Breakaway Plumbing for 5-Section (90’) Boom Configurations Installation: Boom Plumbing...
CHAPTER 3 BOOM PLUMBING FOR 6-SECTION (90’ AND 100’) FIGURE 14. Inner Boom Plumbing for 6-Section (90’ and 100’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 29
INSTALLATION FIGURE 15. Outer Boom and Breakaway Plumbing for 6-Section (90’ and 100’) Boom Configurations Installation: Boom Plumbing...
CHAPTER 3 BOOM PLUMBING FOR 7-SECTION (120’) FIGURE 16. Inner Boom Plumbing for 7-Section (120’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 31
INSTALLATION FIGURE 17. Inner Boom Plumbing Example for 7-Section (120’) Boom Installation: Boom Plumbing...
Page 32
CHAPTER 3 FIGURE 18. Mid Boom Plumbing for 7-Section (120’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 33
INSTALLATION FIGURE 19. Mid Boom Plumbing Example for 7-Section (120’) Boom Installation: Boom Plumbing...
Page 34
CHAPTER 3 FIGURE 20. Outer Boom and Breakaway Plumbing for 7-Section (120’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 35
INSTALLATION FIGURE 21. Outer Boom Section Valve Plumbing Example for 7-Section (120’) Boom FIGURE 22. Breakaway Tip and Protection Shield Example for 7-Section (120’) Boom1 Installation: Boom Plumbing...
CHAPTER 3 BOOM PLUMBING FOR 7-SECTION (132’) FIGURE 23. Inner Boom Plumbing for 7-Section (132’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 38
CHAPTER 3 FIGURE 25. Outer Boom Plumbing Example for 7-Section (132’) Boom Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 39
INSTALLATION FIGURE 26. Outer and Breakaway Boom Plumbing for 7-Section (132’) Boom Configurations Installation: Boom Plumbing...
CHAPTER 3 BOOM PLUMBING FOR 7-SECTION (135’) FIGURE 27. Inner Boom Plumbing for 7-Section (135’) Boom Configurations Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 41
INSTALLATION FIGURE 28. Inner Boom Fold 2 Example for 7-Section (135’) Boom FIGURE 29. Inner Boom Coupling Example for 7-Section (135’) Boom FIGURE 30. Inner Boom Fold 1 Example for 7-Section (135’) Boom Installation: Boom Plumbing...
Page 42
CHAPTER 3 FIGURE 31. Inner Boom Feed Example for 7-Section (135’) Boom Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 44
CHAPTER 3 FIGURE 33. Outer Boom Section Valve Example for 7-Section (135’) Boom FIGURE 34. Outer Boom Feed Example for 7-Section (135’) Boom Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 45
INSTALLATION 1. Disassemble the boom tube section that sticks out in the front of the boom truss. 2. Dismount the bracket holding the tube section. 3. Remount the tube bracket to the truss rib where the boom spot light is mounted. NOTE: The boom spot may have to be moved to the other mounting holes on the rib.
Page 46
CHAPTER 3 FIGURE 36. Outer Boom Fold 2 Example for 7-Section (135’) Boom Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 47
INSTALLATION FIGURE 37. Outer and Breakaway Boom Plumbing for 7-Section (135’) Boom Configurations Installation: Boom Plumbing...
Page 48
FIGURE 38. Boom Tip Example for 7-Section (135’) Boom FIGURE 39. Breakaway Outer Boom Tip Example for 7-Section (135’) Boom FIGURE 40. Breakaway Inner Boom Tip Example for 7-Section (135’) Boom Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
INSTALLATION TIP PROTECTOR BRACKET NOTE: Tip protector brackets (P/N 107-0172-759, 107-0172-760, and 107-0172-761)are not used on 135’ and 132’ boom configurations. 1. Locate the foam marker bracket or a standard tip protector shield bracket at the outer end of each boom tip. FIGURE 41.
Page 50
CHAPTER 3 FIGURE 42. Boom Recirculation for Case Patriot 50 Series System Drawing - 7 Section Plumbing Components (P/N 054-2005-027 Rev. A) Page 1 of 4 Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 51
INSTALLATION FIGURE 43. Boom Recirculation for Case Patriot 50 Series System Drawing - 6 Section Plumbing Components (P/N 054-2005-027 Rev. A) Page 2 of 4 Installation: System Drawings...
Page 52
CHAPTER 3 FIGURE 44. Boom Recirculation for Case Patriot 50 Series System Drawing - 5 Section Plumbing Components (P/N 054-2005-027 Rev. A) Page 3 of 4 Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 53
INSTALLATION FIGURE 45. Boom Recirculation for Case Patriot 50 Series System Drawing - Electronic Components (P/N 054-2005-027 Rev. A) Page 4 of 4 Installation: System Drawings...
Page 54
CHAPTER 3 Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
S ETUP AND OPERATION CHAPTER C H A P T E R 4 SETUP ENABLE MAIN PRODUCT RECIRCULATION To turn on main product recirculation: UT Menu User Settings RCM-Sprayer Tools Menu Rates Confirm Menu Setup 1. Open the UT Menu and select the RCM-Sprayer Menu button. 2.
• Either enable the Auto Recirculate feature or manually initiate recirculation by selecting the Recirculation softkey on the Home page. Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
SETUP AND OPERATION WHAT TO EXPECT WHILE RECIRCULATION IS ACTIVE NOTE: When operating in Auto Recirculation Mode, it is recommended to adjust the Standby PWM% value so that recirculation pressure is close to the application pressure used during application. When recirculation is active: •...
Page 58
CHAPTER 4 Boom Recirculation Installation and Operation Manual for Case IH 50 Series Patriot Sprayers...
Page 59
Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.
Page 61
Bring the defective part and proof of purchase to your Raven dealer. If the dealer approves the warranty claim, the dealer will process the claim and send it to Raven Industries for final approval. The freight cost to Raven Industries will be the customer’s responsibility.
Page 62
WHAT IS NOT COVERED BY THE EXTENDED WARRANTY? Raven Industries will not assume any expense or liability for repairs outside our facility without written consent. Raven Industries is not responsible for damage to any associated equipment or products and will not be liable for loss of profit, labor, or other damages.