between Fault and another operational state. This guarantees that a
hard fault will ultimately latch the unit into Fault. If a recycle
decision is made, the unit remains in the Fault state for, an
additional 0.5 second before cycling back to the original state.
If the unit enters Fault from HTD, the HTD countdown will
continue.
While the unit is in the Fault state, the Fault LED flashes. Once the
unit leaves the Fault state, the Fault LED is OFF.
If the unit is latched into the Fault state, the Fault LED flashes. To
exit the latched Fault state, the user must clear the fault cause, then
toggle the RESET switch. The amplifier returns to Standby.
5.6.7.2

Fault log

A fault log is available to the user via either the remote panel or the
CPI supplied remote software. Refer to either chapter 3 (Figure 3-5)
or to Appendix B for more information on how to access the log.
5-9
Doc. 01031254 Rev. 1