Table 3-2. Helix And Rf Settings Fault And Alarm Ranges - CPI T04CO Installation & Operation Manual

Mpa hub mount
Table of Contents

Advertisement

c.
These functions are used to set alarm and fault limit levels. The
factory set values for these functions for checkout are shown in
Table 3-2.

Table 3-2. Helix and RF Settings Fault and Alarm Ranges

Minimum
Fault Name
Setting
Low RF
0 W
Alarm
Low RF
0 W
Fault
High RF
0 W
Alarm
High RF
0 W
Fault
High
0W
Reflected
RF Fault
Helix Over
8.2 kV
Voltage
Helix Under
0.00 kV
Voltage
Helix Over
5.0 mA
Current
Helix voltage
1.00 kV
in standby
Doc. 01031254 Rev. 1
For all the choices available on the FUNCTION submenu, refer to the
message list for the FUNCTION key in Figure 3-5.
Press FUNCTION until.
The display reads "RF INHIBIT NO".
If the display reads "Yes" use the
value to "NO" and press ENTER to accept the new value.
Factory
Default
Preset
Settings
0 W
0 W
0 W
0 W
425
425 W
475
475 W
25 W
25 W
TWT NPV +
9.0 kV
300V
TWT NPV -
8.2 kV
300V
10.0 mA
10.0 mA
4.00 kV
4.00 kV
keys to change the
Maximum
Setting
Remarks
600 W
See 3.8 for normal
operation.
600 W
See 3.8 for normal
operation.
600 W
See 3.8 for normal
operation.
600 W
See 3.8 for normal
operation.
40 W
Factory Set. Do not
change.
9.3 kV
Factory Set. Do not
change.
8.9 kV
Factory Set. Do not
change.
25.0 mA
Factory Set. Do not
change.
7.5 kV
Factory Set. Do not
change.
M P A H U B M O U N T
Note:
3-13