If a fault occurs during heater warmup, the FLT LED lights. If this
occurs, press RESET. If RESET fails to clear the fault, disconnect
AC power from the unit and refer to Chapter 5.
NOTE: If the system includes a Remote Control Unit skip to 3.6.1.2
Otherwise, refer to 3.6.1.1.
3.6.1.1
Connect the serial interface port (J6) to an IBM compatible
computer with a user-supplied cable. Power up the amplifier with
high-voltage OFF (XMT LED not blinking or lighted). Refer to
Appendix B, for a description of the CPI supplied Setup & Remote
control software program. Refer to table 3-2 and record factory set
values for each parameter.
3.6.1.2
In the following procedure you check and record the values
currently set for the amplifier. You will be able to change these
values to the desired operational values before you place the
amplifier in operational service. If you want to verify RF output
levels, connect a power monitor to amplifier connector J4 (40 dB
nominal coupling) before you power up the amplifier.
Proceed as follows:
a.
b.
3-12

Check Factory Set Values via a Computer

Check Factory Set Values via RCU

Press the LCL/RMT switch once for RMT control mode
(RMT LED lighted).
Set the Remote Control Unit AC Power Switch to ON.
I N I T I A L P O W E R - O N A N D C H E C K O U T
Installation and Operation Manual