Table 4-1 Notes:
1. Outputs are dry-circuit relay contacts rated up to 50 VDC, 50 mA.
2. External interlocks and RF Inhibit inputs are optically isolated. Maximum open circuit
voltage present is 16 VDC. Typical operating current is 3 mA.
3. The RF Inhibit requires a maintained closed-contact with RF Inhibit return for normal
operation. (An open will cause a RF Inhibit.) This RF Inhibit command is executed
regardless of the current control mode.
The External Interlocks (both Latching and Non-latching) require a maintained closed-
4.
contact with their respective interlock returns for normal operation. (An open will cause
either a Fault or RF Inhibit condition.)
Pins 'R' through 'Y' are used only when the Switch Option has been installed.
5.
NOTE: For alternate switch configuration options, Table 4-1 does not apply. Refer to
6.
Appendix G (Hybrid Switch Option) for details.
Doc. 01031254 Rev. 1