First Time Pre-Power Procedure - CPI T04CO Installation & Operation Manual

Mpa hub mount
Table of Contents

Advertisement

Press the FUNCTIONS key to access the FUNCTIONS menu.
Press the FUNCTION key
choices listed below the FUNCTION box. In the REMOTE mode
use the
ENTER to accept the new value and then use the FUNCTION key
to return to the Main Menu (scroll to the end of the list) or press the
Meters key one time. In the LOCAL mode you can scroll through
the FUNCTION list, but you cannot change the parameter values.
3.4 Operation with PC Computer and Setup
& Remote Control Software
This software allows the user to set up and remotely control the
MPA via a PC computer running in DOS mode with the CPI
supplied remote software. The functions, controls and monitors are
the same as those accessed by the remote control panel.
Refer to Appendix B for a complete description of operation with
this software program.

3.5 First Time Pre-Power Procedure

Before applying prime AC power to the MPA Hub Mount, verify
that the following conditions are met:
• AC prime power is 100 - 240 VAC +/- 10%, 47-63 Hz, as
• The AC power cord is connected to J1, but the AC power is not
• A ground strap is connected from the station's ground bus to
• The RF Input and RF Output are connected to a matched source
• All RF connections are terminated and tight.
3-10
keys to raise or lower the parameter value. Press
indicated by the label located on exhaust end of unit, and single
phase.
turned on.
the 6-32 ground screw-mounting hole located on the amplifier
front panel.
and test load. RF input power is off.
I N I T I A L P O W E R - O N A N D C H E C K O U T
repeatedly to scroll through the
Installation and Operation Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

T04uo

Table of Contents