Initial Check, High-Voltage On - CPI T04CO Installation & Operation Manual

Mpa hub mount
Table of Contents

Advertisement

d.
e.
f.
Press FUNCTION to return to the Main Menu.
NOTE: The amplifier should be in the STANDBY mode at this time.
Successful completion of steps (a) through (c) and 3.6.1.1 and 3.6.1.2
indicates:
3.6.2
Initial Check, High Voltage ON
Proceed as follows:
a.
b.
c.
3-14
Press FUNCTION until.
The display reads "LOW RF ALARM 0N"
Continue to scroll through the remaining functions and
record the value for each parameter until you reach the last
item on the list.
You now have a listing of the factory set values for the items
available via the FUNCTION mode.
• Self tests were successfully completed.
• Alarm and fault limit levels are properly set.
• The TWT (Traveling Wave Tube) heater is warmed up.
• High Voltage can be turned ON.
Verify that the amplifier output (J8) is terminated with a RF
load capable of dissipating full rated power.
Verify that the RF Drive is OFF.
Verify that the RMT LED is not lighted.
I N I T I A L P O W E R - O N A N D C H E C K O U T
Installation and Operation Manual