Table G-3 Cable Connections - CPI T04CO Installation & Operation Manual

Mpa hub mount
Table of Contents

Advertisement

Table G-3 Cable Connections

Item
G.2.3
Coaxial Cable
Install the coaxial cables WX1 and WX2 between Coaxial Input
Assembly and the amplifier's input port: output 1 to PA1 and
output 2 to PA2.
G.2.4
Prime Power Cable
Check the main section of this manual for proper input voltage
before connection.
G.3.0
System Operation
G.3.1
General
This section contains instructions for operating the hybrid
combiner subsystem. For operation of the amplifier, see other
sections of this manual. The hybrid combiner is matched at the
input coaxial assembly and at the RF output hybrid. When the
amplifiers are in the transmit mode, output power can be
controlled by varying the subsystem input or by the amplifier's
Doc. 01031254 Rev. 1
From
1
W1P5
2
W2P6
3
W4P5
4
W3P3
5
W5P1
6
W6P9
7
W7P10
8
User's RS485
9
User's M&C
MPA Hub Mount I&O Manual
To
PA1-J5
PA1-J6
PA2-J5
PA2-J6
S1-J1
S2-J1
S3-J3
A5-J1
A5-J2
Termination connector
must be installed
Note
Appendix G-9

Advertisement

Table of Contents
loading

This manual is also suitable for:

T04uo

Table of Contents