GRAUPNER 33124 Manual page 34

Table of Contents

Advertisement

VARIO
m/1s
H
RXSQ
0.0
m/3s
ALT
0.0
0
m/10s
0.0
L
If attached to the receiver, this screen will display the
data acquired by a Vario module, Order No. 33601.
The displayed items are as follows:
Value
Explanation
ALT
current altitude
RXSQ
Signal strength of the signal received
by the receiver in %, see page 209.
MAX
the preset maximum altitude limit
relative to starting location at which,
when exceeded, will cause an audible
warning to be sounded
MIN
the preset minimum altitude limit
relative to the starting location at
which, when underrun, will cause an
audible warning to be sounded
m/1 s
m/1 s ascent/decent rate
m/3 s
m/3 s ascent/decent rate
m/10 s
m/10 s ascent/decent rate
34
Transmitter description - Telemetry data display
ELECTRIC AIR MODULE
0.0V
ALT
0
BAT1
0.0V
MAX
0m
T1
BAT2
MIN
0.0V T2
0m
0.0V
ALT
BAT1
0.0V
T1
BAT2
0.0V T2
If attached to the receiver, this screen will display
the data acquired by an Electric-Air module, Order
No. 33620. More details about this module can be found
in the appendix or in Internet at www.graupner.de in the
web page for the given product.
Depending on how this module is equipped with
sensors, this screen can permanently display the data
shown in the adjacent table.
The current voltage of up to two batteries (BAT1 and
BAT2), up to two temperature measurements (T1 and
T2), current altitude with respect to the starting location,
the model's ascent/decent rate in m/1 s and m/3 s and,
in the middle of the screen, the current draw currently
being taken from a power source.
Along the right edge of the screen is a table of
alternating values for cell voltages at balancer
connections (L) or voltages for up to 7 attached battery
cell packs (H).
The displayed items are as follows:
Value
0A
0
V
0m
1L0.00
A
0m/1s
2L0.00
0m/3s
3L0.00
BAT1 / BAT2
4L0.00
0°C
5L0.00
ALT
6L0.00
m/1 s
0°C
7L0.00
m/3 s
0A
0
0m
1H0.00
T1 / T2
0m/1s
2H0.00
L or H
0m/3s
3H0.00
4H0.00
0°C
5H0.00
6H0.00
0°C
7H0.00
GENERAL MODULE
If attached to the receiver, this screen will display the
data acquired by a General-Engine module, Order
No. 33601, or a General-Air module, Order No. 33611.
More details about these modules can be found in the
Explanation
current voltage
current current
battery 1 or 2
current altitude
m/1 s ascent/decent rate
m/3 s ascent/decent rate
temperature of sensor 1 or 2
cell voltage of cells 1 ... 14 (14 max)
L = balancer connection 1
H = balancer connection 2
CELL V
1:0.00
E FUEL F
2:0.00
BAT1
0.0V
3:0.00
4:0.00
T1
0°C
5:0.00
BAT2
6:0.00
0.0V T2
0°C
0
ALT
0m
BAT1
E FUEL F
0m1
0.0V
0m3
POWER
T1
0°C
0.0V
BAT2
0.0A
0.0V T2
0°C
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mc-32 hott

Table of Contents