GTH TX/RX Loopback Connections
Refer to
Figure 1-2, page 9
four receivers (RX0, RX1, RX2 and RX3) and the four transmitters (TX0, TX1, TX2 and TX3).
Use eight SMA female-to-female (F-F) adapters
receive cables as shown in
•
TX0_P → SMA F-F Adapter → RX0_P
•
TX0_N → SMA F-F Adapter → RX0_N
•
TX1_P → SMA F-F Adapter → RX1_P
•
TX1_N → SMA F-F Adapter → RX1_N
•
TX2_P → SMA F-F Adapter → RX2_P
•
TX2_N → SMA F-F Adapter → RX2_N
•
TX3_P → SMA F-F Adapter → RX3_P
•
TX3_N → SMA F-F Adapter → RX3_N
To ensure good connectivity, it is recommended that the adapters be secured with a wrench;
Note:
however, do not over tighten the SMAs.
X-Ref Target - Figure 1-6
X-Ref Target - Figure 1-7
VC7215 Getting Started Guide
UG970 (Vivado Design Suite v2015.1) April 27, 2015
to identify the P and N coax cables that are connected to the
Figure 1-7
and detailed below:
Figure 1-6: SMA F-F Adapter
Figure 1-7: TX-To-RX Loopback Connection Example
www.xilinx.com
Chapter 1: VC7215 IBERT Getting Started Guide
(Figure
1-6), to connect the transmit and
12