Chapter 5: Powering On the Switch

Powering On the Switch

92
For power supply requirements, refer to "Power Supplies" on page 47. To
power on the chassis, perform the following procedure:
1. Verify that the DC power supply is powered off. If there are two DC
power supplies, verify that both units are powered off.
2. Connect the power cable to the PWR 1 - PWR 2 connector on the top
panel. Refer to Figure 47.
Figure 47. Connecting the Power Cable to the PWR 1 - PWR 2 Connector
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord.  E3
3. Connect the other end of the power cable to the DC power supply.
Refer to the documentation included with the unit for instructions.
4. Power on the DC power supplies.
Note
The switch does not have an On/Off switch.