Powered Device Classes For Poe And Poe; Table 3: Twisted Pair Cable For Powered Devices On The At-Ie200-6Fp And At-Ie200-6Gp Switches; Table 4: Poe And Poe+ Powered Device Classes - Allied Telesis IE200 Series Installation Manual

Industrial ethernet switches
Hide thumbs Also See for IE200 Series:
Table of Contents

Advertisement

Powered Device
Classes for PoE
and PoE+
Table 3. Twisted Pair Cable for Powered Devices on the AT-IE200-6FP
Cable Type
Standard TIA/EIA 568-
B-compliant Category 3
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 16 MHz.
Standard TIA/EIA 568-
A-compliant Category 5
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-
B-compliant Enhanced
Category 5 (Cat 5e)
shielded or unshielded
cabling with 100 ohm
impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-
B-compliant Category 6
or 6a shielded cabling.
The PoE and PoE+ standards define five powered device classes. The
classes are defined by the power requirements of the powered devices.
The classes are shown in Table 4. The AT-IE200-6FP and AT-IE200-6GP
Switches support all five classes.
Table 4. PoE and PoE+ Powered Device Classes
Class
0
1
2
and AT-IE200-6GP Switches
10Mbps
PoE
PoE+
PoE
No
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Maximum
Power Output
Usage
at the Switch
Default
15.4W
Optional
4.0W
Optional
7.0W
IE200 Series Installation Guide
100Mbps
1000Mbps
PoE+
PoE
No
No
No
Yes
Yes
Yes
Yes
Yes
PD Power
Range
Port
.044W to
12.95W
0.44W to 3.84W
3.84W to 6.49W
PoE+
No
No
Yes
Yes