Table 20 lists the vibration, shock, and rough handling specifications for
the AT-IE200-6FP and AT-IE200-6GP Switches.
Table 20. Vibration, Shock, and Rough Handling Specifications for the AT-
IE200-6FP and AT-IE200-6GP Switches
Vibration
IEC60068-2-6
Shock
IEC60068-2-27
Rough Handling
IEC60068-2-31
Note
Resonance occurs in the 18-22Hz range.
Note
If the switch is installed on a DIN rail, Allied Telesis recommends
installing DIN rail end clamps on both sides of the device to prevent
damage or network traffic loss from vibration or shock.
Wall Installation
2g @ 10-150Hz
5g @ 1-35Hz
50g @ 11m/sec
1 meter drop
IE200 Series Installation Guide
DIN Rail Installation
1g @ 10-150Hz
5g @ 1-35Hz
30g @ 11m/sec
1 meter drop