Figure 7: Example 1 Of The Alarm In (Alm In) Connector - Allied Telesis IE200 Series Installation Manual

Industrial ethernet switches
Hide thumbs Also See for IE200 Series:
Table of Contents

Advertisement

The example in Figure 7 shows the Alarm In connector attached to a door
sensor. The sensor is installed such that it is closed (on) when the door is
closed and open (off) when the door is open.
Door Sensor:
Door closed - circuit closed
Door open - circuit open
Figure 7. Example 1 of the Alarm In (ALM IN) Connector
To have the switch generate an alarm when someone opens the door, you
enter the following ALARM FACILITY INPUT-ALARM command. The
command configures the switch to generate an alarm when the state of the
sensor changes from closed to open.
awplus(config)#alarm facility input-alarm 1 alarm-
position open
The alarm remains active until the door is closed again.
In the example in Figure 8 on page 38, the Alarm In connector is
connected to a temperature sensor. The sensor is configured to be open
(off) at temperatures of 30° C or below and closed (on) at temperatures
above 30° C.
IE200 Series Installation Guide
Alarm In connector:
Alarm triggered when circuit
changes to open.
37