Adding and dispensing process chemicals
Checking
consumption

Refill indicator

Dispensing liquid
process
chemicals
52
Push the suction lance into the opening of the container and secure
the lid. Observe the colour coding.
Feed the suction lance into the container until it reaches the
bottom.
Wipe up any spilled process chemical thoroughly.
Place the container back in the drawer in the side cabinet.
Close the drawer. Ensure that the dispensing tubes and cords are
not kinked or trapped.
The dispensing system must then be vented (see "Settings  /
Venting DOS").
Check consumption regularly by checking the fill levels in the supply
containers and replace containers in good time to avoid the
dispensing system being sucked completely dry.
When the fill level is low in the
cleaning detergent you are reminded to replenish it.
Confirm the message shown with OK and
refill the liquid cleaning detergent as described.
If the liquid cleaning detergent has run out, the machine will be
locked for further use.
It will be ready for use again when the supply container has been
replaced.
For adjusting dispensing concentration, see "Further settings/
Dispensing systems."
DOS 1
supply container for liquid
Refill DOS