WAGO TO-PASS® Web
10.4.1

Example of HTTP Response

The HTTP response consists of both header and data string, which are separated
by an empty line (<CR><LF> = Carriage Return + Line Feed).
HTTP/1.1 200 OK<CR><LF>
Date: Fri, 19 Sep 2008 11:22:23 GMT<CR><LF>
Server: Apache <CR><LF>
Content length: 31<CR><LF>
Keep alive: timeout=15, max=100<CR><LF>
Connection: Keep-Alive<CR><LF>
Content type: text/html<CR><LF>
<CR><LF>[...]]
Values stored:08/09/19,13:22:23
The header depends on both installation and Web portal settings and may deviate
from the illustration shown above.
Beispiel für Sollwertvorgaben (Zeilenumbrüche zur besseren Lesbarkeit):
Values stored:12/09/05,12:31:57
?AO1=12.13&AO2=12.52&AO3=0&AO4=0&AO5=0&AO6=0&AO7=0&AO8=0
&DO1=0&DO2=0&DO3=1&DO4=1&DO5=0&DO6=0&DO7=0&DO8=0
&CV2=000001F4
&CR2=1
&CE2=1
&CV3=0000C350
&CE3=0
761-114 Telecontrol Module Compact, 2 AI, Web, MODBUS485
WAGO-TO-PASS® 761
Manual
Version 1.0.0