Pos : 57.8 /Serie 767 (WAGO-SPEED WAY)/Eins atz in sicherheitsg erichteten Anwendung en/767- xxxx_M aß nahmen und Aufl agen für die ungesc hir mte Spannungs versorgung des Moduls_5 @ 11\mod_1317280618487_21.doc x @ 80006 @ 2 @ 1
11.4
Measures and Conditions for Unshielded Power
Supply of the Module
Measures when using connecting cables with no shielding!
If you use unshielded connecting cables to supply interference-free modules, you
are required to install the connecting cables according to EN 60204-1 or
EN ISO 13849-2 in a cable duct, armored conduit or shielded installation space.
The measures must be suitable to ensure fault exclusion (short circuit between any
two conductors) according to EN 60204-1 or EN ISO 13849-2. The fault
exclusion must apply to supply voltages UA and external voltages (e.g. U
Please also note the cable routing in the outlet area of the protective measure (e.g.
outlet area from the armored conduit/cable duct).
Pos : 57.9 /Dokumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1