9. Technical Specifications

Unless otherwise specified, the technical specifications applied are for
TAO3000 four-channel series only, and Probes attenuation set as 10X. Only if
the oscilloscope fulfills the following two conditions at first, these specification
standards can be reached.
 This instrument should run for at least 30 minutes continuously under the
specified operating temperature.
 If change of the operating temperature is up to or exceeds 5℃, do a
"Self-calibration" procedure (see "How to Implement Self-calibration" on
P13).
All specification standards can be fulfilled, except one(s) marked with the word
"Typical".

Oscilloscope

Performance Characteristics
Bandwidth
Vertical Resolution (A/D)
Channel
Waveform Capture Rate
Multi-level Gray Scale Display &
Color Temperature Display
(Use gray scale to indicate frequency of
occurrence, where frequently occurring
waveform are bright.)
Magnifier Function
(The magnifier window can display the
magnified wave of the wave selection
horizontally and vertically.)
Mode
Acquisition
Sample rate
(real time)
9.Technical Specifications
TAO3074
TAO3074A
TAO3104
TAO3104A
TAO3074
TAO3074A 8 bits/12 bits/14 bits
TAO3104
TAO3104A 8 bits/12 bits/14 bits
TAO3074
TAO3104
TAO3074A
TAO3104A
Normal, Peak detect, Averaging
TAO3074
TAO3104
TAO3074A
TAO3104A
120
Instruction
70 MHz
100 MHz
8 bits
8 bits
4
45,000 wfms/s
Support
Not support
Support
Four CH
Dual CH*
Single CH
Four CH
8 bits
Dual CH* 500 MSa/s
mode
Single CH 1 GSa/s
12 bits
Four CH
mode
Dual CH* 250 MSa/s
250 MSa/s
500 MSa/s
1 GSa/s
250 MSa/s
125 MSa/s