Input Voltage - Xantrex Freedom XC2000-230V Owner's Manual

Inverter/charger
Table of Contents

Advertisement

Operating Limits

Input Voltage

The allowable Freedom XC input battery voltage ranges are
shown in the following table:
Table 12 Input battery voltage range
Operating
Battery
Condition
Voltage
Full
LBCO –
Operating
17.0 V
Range
Low
Voltage
< LBCO+0.2 V
Recovery
b
To set LBCO, see Adjusting Settings in Configuration Mode on page 53.
c
To set LBCO Shutdown Delay Timer, see Input Voltage on page 68.
68
Comment
Assuming the battery is full, the
inverter/charger will operate until
battery voltage goes past below
b
LBCO
and LBCO Shutdown
c
delay timer
.
Inverter is able to recover and
continue to operate.
Operating
Battery
Condition
Voltage
Low
Voltage
< LBCO
Shutdown
Instant Low
Voltage
< 9.0 V
Shutdown
Freedom XC 2000 - 230V Owner's Guide
Comment
The buzzer sounds a single 1 s
low battery alarm beep and the
LCD screen shows error code
E01. After LBCO Shutdown
delay timer runs out, the unit
shuts down inverter output. The
buzzer stops beeping and the
LCD screen shows error code
E01.
After 2 s below the limit, the unit
shuts down inverter output
completely. LCD screen turns
off completely.