Xantrex Freedom XC2000-230V Owner's Manual page 25

Inverter/charger
Table of Contents

Advertisement

Item
7
DC terminal opening for routing (+) positive DC cable.
8
LED alert indicator for reverse DC polarity.
9
AC output terminal opening for routing AC output wiring.
10
AC input terminal opening for routing AC input wiring.
c Reserved for future use. AC cover.
11
Mounting flanges on both sides allow you to mount the
12
inverter/charger permanently on deck or on a wall.
Ventilation grille (openings) must not be obstructed for
the proper operation of the cooling fan and
inverter/charger. When the inverter/charger is mounted,
13
the ventilation grille must not point up or down.
Cooling fans turn on when the internal temperature
reaches a set point temperature.
c Reserved for future use. Supplementary protector
14
with reset button.
AC Out Neutral-to-Earth Bond. See "AC Output Neutral
15
Bonding Option (Earth Relay Function)" on page 21 for
more information.
975-0821-01-01
Description
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the bolt on the DC
n
earth lug to a torque of 2.6 N-m of force.
Apply an anti-corrosion compound to the copper wire prior
n
to connecting to the DC earth lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
AC and DC Panel
9