Xantrex_PRO1800.book Page 5 Tuesday, April 24, 2007 11:33 AM

Operating Limits

Power Output

Input Voltage

975-0263-01-01
The XM 1800 can deliver up to 1000 watts (XM 1000) or 1800 watts
(XM 1800) continuous power. The wattage rating applies to resistive
loads such as incandescent lights.
The allowable XM 1800 input voltage ranges are shown in the following
table:
Operating
Condition
Voltage Range
Normal
11–15.0 V
Optimum
12.0–13.0 V
Performance
Low Voltage Alarm
11.0 V or less
Low Voltage
Less than
Shutdown
10.5 V
High Voltage
15.5 V or more
Shutdown
Operating Limits
Comment
The low battery alarm beeps once
every two seconds and the display
shows fault code E01 alternating with
the battery voltage.
The low battery alarm beeps every
second and the display shows fault
code E02 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect the
battery from being over-discharged.
The over-voltage alarm beeps every
second and the display shows fault
code E03 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect
itself from excessive input voltage.
Note: Although the XM 1800
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.