Basic Installation Procedures
Connecting the Equipment Earth
ELECTRIC SHOCK HAZARD
Never operate the Freedom XC without properly connecting the
equipment earth. A shock and energy hazard could result from
improper earthing.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
The Freedom XC has an earth lug on the side of the unit as shown
in Connecting the Equipment Earth. Follow the guidelines in
Earthing Locations on page 26 to connect the inverter/charger's
chassis to earth.
Figure 8 DC Panel Connections
1
1
DC earthing lug
26
WARNING
Earthing Locations
You must connect the equipment earth lug to an earthing point—
usually the vehicle's chassis or DC negative bus earth—using
recommended copper wire (if insulated then green insulation with
or without one or more yellow stripes) or larger.
Make sure to tighten the bolt on the DC earth lug to a torque of
2.6 N-m of force. Apply an anti-corrosion compound to the copper
wire prior to connecting to the DC earth lug.
For recommended equipment earth cable size, see below.
Table 6 Equipment DC earth cable size
Minimum equipment cable size
Application
(Stranded copper cable is required)
Recreational
10mm
Vehicle
55mm
Marine
NOTE: There are no restrictions on length for the equipment
earth cable but try to make it as short as practical to a secure
chassis connection. In general, the equipment earth cable size
must not be smaller than one size than the supply cable.