Testing the GFCI

Operating Limits

Power Output

Input Voltage

975-0555-01-01
Perform the following GFCI Test:
1. Turn the inverter on.
2. Plug a simple appliance, such as a lamp, in the GFCI outlet. Turn the
lamp on.
3. Press the TEST button. Observe a clicking sound. The lamp turns off.
4. Press the RESET button all the way to the bottom until the button locks
into position. The lamp turns back on.
Important:
Perform this GFCI test once a month to ensure continued
functionality of the GFCI.
The
XPower Inverter 3000
3000 W for five minutes.
The allowable inverter input (battery) voltage ranges are shown in the
following table:
Operating Condition Voltage Range
Normal
Optimum
Performance
Low Voltage Alarm
Low Voltage
Shutdown
High Voltage
Shutdown
can deliver up to 2500 W continuous and up to
Comment
10.5–15 V
n/a
12.0–13.0 V
n/a
11.0 V or less
The audible low battery
alarmsounds.
less than 10.5 V The inverter shuts down to protect the
battery from being over-discharged.
15 V or more
The inverter shuts down to protect
itself from excessive input voltage.
Note: Although the inverter
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.