Xantrex Freedom XC2000-230V Owner's Manual page 71

Inverter/charger
Table of Contents

Advertisement

Setting Name
07
Output Frequency
08
Output Voltage
Inverter Output Power
09
Limit (Freedom XC 2000
- 230V)
Inverter Output Power
10
Limit Timer
11
Transfer Mode
Utility AC Under Voltage
12
Level
975-0821-01-01
Setting
Default
Range of
Number
Value
Values
50
50
60
220
230
230
240
2.0
0.1 to 2.0
300
1 to 300
APL(appliance)
APL
UPS (UPS)
180
170 to 220
Description
After changing the output frequency setting, turn the unit off and
then on again, in order for the change to take effect.
In VV
The wattage setting value can be adjusted by 100-W increments.
Use with Inverter Output Power Limit Timer especially when
pairing with a lithium ion battery. 0.1 is equivalent to 100 W.
When the range is from 1 to 20, the timer setting value can be
adjusted by 1-s increments. When the range is from 20 to 300, the
timer setting value can be adjusted by 10-s increments.
Use with Inverter Output Power especially when pairing with a
lithium ion battery. The timer is automatically disabled if the
maximum Inverter Output Power limit is selected.
Selecting APL- appliance sets the transfer time from line to battery
to 20 ms. Selecting UPS (uninterruptible power supply) sets the
transfer time from line to battery to 10 ms. NOTE: Do not connect
motor loads when in UPS transfer mode. See Troubleshooting on
page 73.
In VV
Adjusting Settings in Configuration Mode