Input Voltage - Xantrex Freedom X 1200 Owner's Manual

120v sine wave inverter
Table of Contents

Advertisement

Input Voltage

The allowable Freedom X 1200 input battery voltage ranges are
shown in the following table:
Table 11 Input battery voltage range
Operating
Battery
Condition
Voltage
Full
LBCO –
Operating
16.5 V
Range
Low
Voltage
< LBCO+0.5 V
Recovery
c
To set LBCO, see Adjusting Feature Settings in Configuration Mode on page 1.
d
To set LBCO Shutdown Delay Timer, see Input Voltage on page 77.
975-0767-01-01
Comment
Assuming the battery is full, the
inverter will operate until battery
voltage goes past below LBCO
and LBCO Shutdown delay
d
timer
.
Inverter is able to recover and
continue to operate.
Operating
Battery
Condition
Voltage
Low
Voltage
< LBCO
Shutdown
c
Instant Low
Voltage
< 10.2 V
Shutdown
Operating Limits
Comment
The buzzer sounds a single 1 s
low battery alarm beep and the
LCD screen shows error code
E01. After LBCO Shutdown
delay timer runs out, the unit
shuts down inverter output. The
buzzer stops beeping and the
LCD screen shows error code
E01.
After 2 s below the limit, the unit
shuts down inverter output
completely. LCD screen turns
off completely.
77