Setting Name
Custom Absorption
22
Voltage
23
Custom Float Voltage
Custom Absorption
22
Voltage
23
Custom Float Voltage
Charger Current
24
(Freedom XC 2000 -
230V)
26
Charger Ignition Control
Equalize Charging for
27
Flooded Battery
AC Input Breaker for
28
Load Share
Reset all settings to their
99
default values
975-0821-01-01
Setting
Default
Range of
Number
Value
Values
14.6
12.0 to 18.0
13.5
12.0 to 18.0
14.6
12.0 to 17.0
13.5
12.0 to 17.0
80
5 to 80
OFF(OFF)
OFF
AT0 (Auto-ON)
ENA (enable)
DIS
DIS (disable)
30
5 to 30
NDF (as is)
ndf
DEF (default)
Description
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
The voltage setting value can be adjusted by 0.1 increments.
Available only when custom battery type is selected.
The current setting value can be adjusted by 5A increments.
See Description of Ignition Control Features on page 40.
This setting is only available when Flooded battery type is
selected. It allows only 1 h of equalize charging once.
The load share feature prioritizes the AC load by reducing the
charge current in order to maintain the total input current to less
than the load share setting.
ndF refers to current settings.
Choose def to restore all settings to their default values.
Adjusting Settings in Configuration Mode