Xantrex Freedom XC2000-230V Owner's Manual page 20

Inverter/charger
Table of Contents

Advertisement

Materials List
Built-in Charge
For the inverter/charger to perform at the
Formulas
highest level, the batteries must be charged
correctly. The Freedom XC has optimized
algorithms for flooded, gel, AGM, custom,
and lithium iron phosphate [LFP (or LiFePO
batteries.
Manual
Over a period of time, the cells in a flooded
Equalization
battery can develop uneven chemical states.
This can result in a weak (undercharged) cell
which, in turn, can reduce the overall capacity
of the battery. To improve the life and
performance of a non-sealed, flooded battery,
the Freedom XC multi-stage charging cycle
includes a manual equalize mode that can be
used, if recommended by the battery
manufacturer.
Dead Battery
Another feature of the Freedom XC is dead
Charging
battery charging. This is the ability to
recharge batteries, even if the battery voltage
has reached 0 VZ.
4
Ignition Control
The Freedom XC provides two user-
selectable options for ignition control:
)]
4
The Freedom XC is factory set to 50 Hz V
Configurable AC
output frequency and 230 V V output
Output Frequency
and Voltage
voltage. It can be configured to 60 Hz for use
in regions outside the EU. The AC voltage
setting can also be configured to either of
three settings: 220, 230, or 240 VV.
Ignition Auto-on: The Freedom XC
n
can automatically turn the
inverter/charger on and off in tandem
with the vehicle's ignition circuit or a
manually operated remote switch.
Ignition Lockout: The Freedom XC
n
features the ability to inhibit the
inverter/charger from operating in the
absence of a voltage signal from a
vehicle's ignition circuit. This is
particularly useful if the inverter/charger
is required to operate only when a
vehicle's engine is running.
Freedom XC 2000 - 230V Owner's Guide

Advertisement

Table of Contents
loading

Table of Contents