Xantrex Freedom XC2000-230V Owner's Manual page 45

Inverter/charger
Table of Contents

Advertisement

ELECTRIC SHOCK HAZARD
Use a screwdriver to loosen the captive nut panel screw.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
Figure 9 Loosening the captive nut panel screw
1
1
Captive nut panel screw
4. Strip a single AC input wire, as appropriate. Strip 10 mm off
the ends of each of the three the wires (tin the exposed
copper wire with lead-free solder using a soldering iron).
5. Remove the knockout and install PG16 (or PG21) strain
relief clamp.
6. Route the wires through the strain relief clamp (not shown in
the figure).
975-0821-01-01
WARNING
Figure 10 Routing the AC input wires
G
N
L
5
1
step 8a
2
step 8b
3
step 8c
4
15mm
5
to circuit breaker
NOTE: AC input hole - install a strain relief clamp (not shown).
7. Locate the Neutral, Earth and Line terminals on the AC input
terminal labeled as N, G, and L respectively.
Basic Installation Procedures
1
3
N
G
L
N
G
L
2
4
29