Step 7: Connecting To Port(S) On The Freedom Xc - Xantrex Freedom XC2000-230V Owner's Manual

Inverter/charger
Table of Contents

Advertisement

Step 7: Connecting to Port(s) on the
Freedom XC
Connecting to ACC Signal
With the ACC, the Freedom XC can be wired to inhibit inverter
operation in the absence of a vehicle's (or vessel's) +12VZ
ignition control signal. This feature can avoid unnecessary battery
drain that would otherwise occur if the inverter/charger was
operated without a charging source such as the vehicle alternator.
To enable ignition control:
1. Ensure that AC and DC power are both OFF.
2. Ensure the vehicle's ignition is turned to OFF position. It is
highly recommended to remove battery power by
disconnecting the vehicle's battery cables. Refer to the
vehicle's user manual for proper instructions on how to
disconnect the battery cables.
3. Locate the vehicle's ignition control wire from the vehicle's
ignition circuit. This wire must be fused appropriately at no
more than 5 A. Refer to the vehicle's user manual for
guidance.
4. Locate the ACC input (ignition signal input) terminal on the
right side of the connector. The left terminal is not used at
this time. See Figure 14
975-0821-01-01
Figure 14 Ignition signal (ACC) input terminal
5. Using a 3mm slot long neck screwdriver, push into the
rectangular slot to release the spring clamp.
6. Insert the ignition control wire into the round ACC input
terminal slot.
7. Pull the screwdriver out to engage the spring clamp and
secure the wire to the terminal.
Basic Installation Procedures
39