3.3. Environmental Conditions
Parameter
Input Voltage (Variant Pa)
Input Voltage (Variant Pb)
Operating Temperature Range
•Up to 4 radio modules
Operating Temperature Range
•5 or 6 radio modules
Storage Temperature Range
Humidity
Altitude (Variant Pa)
Altitude (Variant Pb)
Over-Voltage Category
Pollution Degree
Ingress Protection Rating
Attention: When using the Pb variant with an input voltage higher than 60 V
the router MUST be connected to an earth protection.
NB3000-Line-Hd User Manual 4.2
Rating
24 V
to 60 V
DC
72 V
to 110 V
DC
40 C to +70 C
(Class TX according to EN 50155)
25 C to +55 C
(Class T2 according to EN 50155)
40 C to +85 C
0 to 95% (non-condensing)
up to 4000m
up to 2000m
I
2
IP65 with:
•SIM Cover mounted
•Ethernet Cable or M12 Cap mounted
•Extension Cable or M12 Cap mounted
Table 3.1.: Environmental Conditions
8
( 30% / +5%)
DC
( 30% / +25%)
DC
,
DC