107D 6Bh See "Initialize Data Carrier (Si) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Initialize data carrier (SI)
Command:
Byte
Byte 0
Byte 1
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
This command allows conventional reading and writing of IDC-...-1K read/write
tags that were configured using the EP or SP commands.
68
Content
Command code (6Bh)
Reserved/Ident channel/Toggle bit
Content
Command code (6Bh)
Reserved/Ident channel/Toggle bit
Status
Reply counter
not used
not used
not used
not used
not used
Bit no.
7
6
5
4
3
0
1
1
0
1
-
-
-
-
<Channel>
Bit no.
7
6
5
4
3
0
1
1
0
1
-
-
-
-
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
0
1
1
<T>
2
1
0
0
1
1
<T>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents