See "Enhanced Read Special Fixcode (Es) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Enhanced read special fixcode (ES)
Command:
Byte
Content
Byte 0
Command code (71h)
Byte 1
Word number/Ident channel/Toggle bit
Byte 2
not used
Byte 3
not used
Byte 4
not used
Byte 5
not used
Byte 6
not used
Byte 7
not used
Response:
Byte
Content
Byte 0
Command code (71h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Status
Byte 3
Reply counter
Byte 4
ID code 00h ... FFh
Byte 5
ID code 00h ... FFh
Byte 6
ID code 00h ... FFh
Byte 7
ID code 00h ... FFh
Byte 8
ID code 00h ... FFh
Byte 9
ID code 00h ... FFh
The R/W head attempts to read a special read only code until successful. Only
data that changes is transferred via the interface, i.e. the R/W head transfers data
whenever it reads a new data carrier or whenever it reads a data carrier where
there was previously no R/W head within the detection range.
The status '05h' (read command) is output whenever a data carrier leaves the
detection range.
Note!
The <FixLen> of IDC-...-1K read/write tags is always 6 bytes.
Bit no.
7
6
5
4
3
0
1
1
1
0
<FixLen>
<Channel>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Bit no.
7
6
5
4
3
0
1
1
1
0
-
-
-
-
<Channel>
<Status>
<ReplyCounter>
<ID code>
<ID code>
<ID code>
<ID code>
<ID code>
<ID code>
2
1
0
0
0
1
<T>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
0
0
1
<T>
65

Advertisement

Table of Contents
loading