10D 0Ah See "Single Read Special Fixcode (Ss) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Single read special fixcode (SS)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Byte 9
The R/W head makes only one attempt to read a special read only code.
Note!
The <FixLen> of IDC-...-1K read/write tags is always 6 bytes.
64
Content
Command code (0Ah)
FixLen/Ident channel/Toggle bit
not used
not used
not used
not used
not used
not used
Content
Command code (0Ah)
Reserved/Ident channel/Toggle bit
Status
Reply counter
ID code 00h ... FFh
ID code 00h ... FFh
ID code 00h ... FFh
ID code 00h ... FFh
ID code 00h ... FFh
ID code 00h ... FFh
Bit no.
7
6
5
4
3
0
0
0
0
1
<FixLen>
<Channel>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Bit no.
7
6
5
4
3
0
0
0
0
1
-
-
-
-
<Channel>
<Status>
<ReplyCounter>
<ID code>
<ID code>
<ID code>
<ID code>
<ID code>
<ID code>
2
1
0
0
1
0
<T>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
0
1
0
<T>