31D 1Fh See "Single Write Fixcode (Sx) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Write read only code IPC11 and IDC-..-1K
"Read-after-write" operating mode is not used.
Tags IPC11 can be programmed to behave like the IPC02 read only tag. To do
this, use the commands SX and EX. The code is read when tag type '02' or '11' is
set with the commands SF and EF.
Tags IDC-...- 1K can be programmed to behave like the ICC read only tag. This
programming occupies the first 8 bytes in the tag and occurs when the tag type
'50' is set with the commands SX or EX.
This code is read when tag type '52' is set with the commands SF or EF. If you use
the command SF or EF when tag type '50' is selected, the 4-byte read only code
of the tag is issued.
Single write fixcode (SX)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
...
Byte N
Table 7.7
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
The R/W head makes only one attempt to write a read only code.
58
Content
Command code (1Fh)
FixLen/Ident channel/Toggle bit
FixType
FixType
Data 00h ... FFh
Data 00h ... FFh
Data 00h ... FFh
1)
1) N = <FixLen> + 3
Content
Command code (1Fh)
FixLen/Ident channel/Toggle bit
Status
Reply counter
not used
not used
not used
not used
Bit no.
7
6
5
4
3
0
0
0
1
1
<FixLen>
<Channel>
<FixType> (high byte)
<FixType> (low byte)
<Data>
<Data>
<Data>
Bit no.
7
6
5
4
3
0
0
0
1
1
<FixLen>
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
1
1
1
<T>
2
1
0
1
1
1
<T>
-
-
-
-
-
-
-
-
-
-
-
-

Advertisement

Table of Contents
loading

Table of Contents