IC-KP2-1HB6-2V15B
Commands
Single write configuration (SC)
Command:
Byte
Content
Byte 0
Command code (12h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Reserved
Byte 3
Address in the configuration range
Byte 4
Data 00h ... FFh
Byte 5
Data 00h ... FFh
Byte 6
Data 00h ... FFh
Byte 7
Data 00h ... FFh
Response:
Byte
Content
Byte 0
Command code (12h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Status
Byte 3
Reply counter
Byte 4
not used
Byte 5
not used
Byte 6
not used
Byte 7
not used
The R/W head makes exactly one attempt to write a word to the configuration
range ("Protection Word" or "Control Word") from the address <ConfAddr>.
The password mode must be active so that the R/W head can write to the
configuration range.
If the password mode is deactivated, every data word outside of the write-
protected range can be written to. If you would like to modify the write-protected
range, you must modify the "Protection Word" accordingly.
For example:
With the R/W head on channel 1, one data word (4 bytes) that does not contain
details of the address and data length should be transferred during each read
command (accessed with 00 byte and address 0000). Password mode must be
activated beforehand by transmitting the command Set password mode.
Bit no.
7
6
5
4
3
0
0
0
1
0
-
-
-
-
<Channel>
-
-
-
-
-
<ConfAddr>
<Data byte 3>
<Data byte 2>
<Data byte 1>
<Data byte 0>
Bit no.
7
6
5
4
3
0
0
0
1
0
0
0
0
0
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
0
1
0
<T>
-
-
-
2
1
0
0
1
0
<T>
-
-
-
-
-
-
-
-
-
-
-
-