See "Configuration Store (Cs) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Configuration store (CS)
Command:
Byte
Content
Byte 0
Command code (17h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Mode
Byte 3
unused
Byte 4
unused
Byte 5
unused
Byte 6
unused
Byte 7
unused
Response:
Byte
Content
Byte 0
Command code (17h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Status
Byte 3
Reply counter
Byte 4
unused
Byte 5
unused
Byte 6
unused
Byte 7
unused
The configuration store (CS) command allows you to store the last command sent
to the R/W head in the non-volatile memory of the IDENTControl Compact. The
R/W head executes the command automatically again if the power supply is
interrupted or the IDENTControl Compact is reset.
<Mode>='1' activates the mode.
<Mode>='0' deactivates the mode.
Configuration store is deactivated by default.
Bit no.
7
6
5
4
3
0
0
0
1
0
-
-
-
-
<Channel>
0
0
0
0
0
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Bit no.
7
6
5
4
3
0
0
0
1
0
-
-
-
-
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
1
1
1
<T>
0
0
<Mode>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
1
1
1
<T>
-
-
-
-
-
-
-
-
-
-
-
-
39