Bfh See "Write Param (Wp) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
write param (WP)
Command:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
...
Byte N
1)
Response:
Byte
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
IQH2-...:
IUH-...:
72
Contents
Command code (BFh)
reserved/Ident channel/T oggle bit
reserved
System code
Parameter type
Parameter type
Data length in bytes
Data length in bytes
Data 00 ... FFh
Data 00 ... FFh
Data 00 ... FFh
1)
N = <DataLength> + 7
Contents
Command code (BFh)
reserved/Ident channel/T oggle bit
Status
Reply counter
not used
not used
<SystemCode>
=
<ParamTyp>
=
See handbook of the read / write head
Bit no.
7
6
5
1
0
1
0
<SystemCode>
<ParamTyp> (High Byte)
<ParamTyp> (Low Byte)
<DataLen> (High Byte)
<DataLen> (Low Byte)
Bit no.
7
6
5
1
0
1
0
<ReplyCounter>
-
-
-
-
-
-
'Q' ASCII (51
)
h
'K1' ASCII (4B
31
)
h
h
RP: reads the key (12 characters ASCII from 0 ... F)
from the transponder and the read head
WP: writes the key (12 characters ASCII from 0 ... F)
into the read head
Default key = 'FF FF FF FF FF FF' ASCII
(46
46
46
46
46
46
46
46
h
h
h
h
h
h
h
4
3
2
1
0
1
1
1
1
1
<Channel>
<T>
0
<Data>
<Data>
<Data>
4
3
2
1
0
1
1
1
1
1
<Channel>
<T>
<Status>
-
-
-
-
-
-
-
-
-
-
46
46
46
46
)
h
h
h
h
h

Advertisement

Table of Contents
loading

Table of Contents