Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual page 23

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commissioning
6.2
Connection
Warning!
Incorrect electrical connection
Incorrect connections may damage the system.
Before commissioning, familiarize yourself with the system of communication
between your PROFIBUS DP and the read/write station. Check all connections
before commissioning.
When the supply voltage is connected and the device is initialized, the PWR/ERR
LED lights up green. If the LED lights up red, either the initialization process has
not yet finished or there is a device fault.
6.3
Device settings
Caution!
Device not configured or configured incorrectly
System failure caused by incorrectly configured device
Configure the device prior to commissioning.
You must set the various parameters prior to commissioning.
The parameters are volatile and non-volatile parameters. Volatile parameters are
reset to their default setting when the system is switched off and on again.
Non-volatile parameters
Parameter
R/W head
Data carrier type
PROFIBUS interface
Slave address
Volatile parameters
Parameter
R/W head
Password mode
Password
Configure the read/write head with the described system commands. "99" is
preset as the data carrier type.
Default setting
99
7E
Default setting
Off
00000000
Value range
00 ... FF
00 ... 7E
Value range
on / off
00000000 ... FFFFFFFF
23