See "Enhanced Buffered Write Configuration (Ec) - Pepperl+Fuchs IC-KP2-1HB6-2V15B Manual

Identcontrol compact unit with interface for profibus dp
Hide thumbs Also See for IC-KP2-1HB6-2V15B:
Table of Contents

Advertisement

IC-KP2-1HB6-2V15B
Commands
Enhanced buffered write configuration (EC)
Command:
Byte
Content
Byte 0
Command code (66h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Reserved
Byte 3
Address in the configuration range
Byte 4
Data 00h ... FFh
Byte 5
Data 00h ... FFh
Byte 6
Data 00h ... FFh
Byte 7
Data 00h ... FFh
Response:
Byte
Content
Byte 0
Command code (66h)
Byte 1
Reserved/Ident channel/Toggle bit
Byte 2
Status
Byte 3
Reply counter
Byte 4
not used
Byte 5
not used
Byte 6
not used
Byte 7
not used
The R/W head attempts to write a word in the configuration range to the address
<ConfAddr> until successful. After each write, the status is evaluated and the
system waits until a new data carrier is within the detection range. The command
then starts again from the beginning. In order to write in the configuration range,
the password mode must be active.
The status '05h' (read/write command) is only output when a data carrier leaves
the detection range or is not yet within the detection range when the command is
executed.
If two data carriers enter the read range one immediately after the other, the status
'05h' is not issued between the two readings.
Bit no.
7
6
5
4
3
0
1
1
0
0
-
-
-
-
<Channel>
-
-
-
-
-
<ConfAddr>
<Data byte 3>
<Data byte 2>
<Data byte 1>
<Data byte 0>
Bit no.
7
6
5
4
3
0
1
1
0
0
-
-
-
-
<Channel>
<Status>
<ReplyCounter>
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2
1
0
1
1
0
<T>
-
-
-
2
1
0
1
1
0
<T>
-
-
-
-
-
-
-
-
-
-
-
-
57

Advertisement

Table of Contents
loading