PVC Connections
For this example, we specify CBR as the traffic type, then take the remaining defaults. Enter the
command to obtain the index number of the new traffic descriptor. In this example, the index
trafficdescriptor
number is two (2).
Smart6500 # show trafficdescriptor
========================================================================================
TD#
Traff
Desc
QoS
Type
Type
=========================================================================================
1
NRTVBR
7
0
2
CBR
2
1
176
NRTVBR
2
1
Smart6500 #
Use
to create the PVC; specify the ports through which the connection is established, the
2.
add pvc
VPI/VCI pair to use with each port, and the traffic descriptor to use.
Smart6500 #
add pvc
ConnType(PTP)
Port-1-Number()
Port-1-VPCI()
Port-1-VCI()
Port-2-Number()
Port-2-VPCI()
Port-2-VCI()
Port1-to-Port2TrafficDescriptorIndex()
Port2-to-Port1TrafficDescriptorIndex()
Smart6500 #
The example above creates a PVC between ports 7a1 and 7b2 with VPCI/VCI = 0/100.
3.
Plug the end nodes into the specified SmartSwitch 6500 ports (7a1 and 7b2).
Configure each end node with the proper IP address, subnet mask, and VPCI/VCI pair = 0/100.
4.
The end nodes can communicate with each other through the point-to-point PVC connection.
6.1.2

Point-to-Multipoint PVCs

Instructions in this section describe how to set up a point-to-multipoint connection through your SmartSwitch 6500.
Example: Create a point-to-multipoint connection between a broadcasting workstation on port 7a1 and three other
workstations connected to ports 7a2, 7a3, and 7a4.
Use
1.
add trafficdescriptor
other for the backward direction. For this example, for the forward traffic descriptor, we select UBR
and accept the defaults.
Smart6500 # add trafficdescriptor
TrafficType(UBR)
TrafficDescriptorType(11)
PCRCLP01(100)
QOSCLASS(0)
AalType(5)
Smart6500 #
6-2 SmartSwitch 6500 User Guide
Peak Cell Rate
Sust Cell Rate
(Kb/s)
(Kb/s)
CLP_0
CLP_0+1
CLP_0
0
10872
5436
0
100
0
0
1585
0
:
: 7a1
: 0
: 100
: 7b2
: 0
: 100
: 2
: 2
to create two new traffic descriptors, one for the forward direction, the
< This is the forward descriptor
< We use UBR for this example
:
:
< Take the default values
:
:
:
Max Burst Size
(Kb/s)
CLP_0+1
CLP_0
CLP_0+1
0
2052
0
0
0
0
0
0
0
< Specify first port
< Specify its VPCI
< Specify its VCI
< Specify second port
< Specify its VPCI
< Specify its VCI
< We use our traffic descriptor
Virtual Ports and Static Connections
show
Min Cell Aal Type
Rate
(Kb/s)
0
5
0
5
0
5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartSwitch 6500 and is the answer not in the manual?