2.7.2.

Inspection of the connection to the electrical network

Attention!
When you connect the machine to the electrical network
insure correct connection of all phases!
THE HYDRAULIC AGGREGATE ENGINE MUST NOT BE
OPERATED IN REVERSED MODE FOR MORE THEN 10
SECONDS!!!
2.8.

Filling of the cooling system

Prepare a mixture of the water and the cooling liquid. Keep to the concentration
specified by manufacturer. Remove the cover from the drainage hole. Pour the
mixture into the tank of the cooling system.
When filling the tank with the cooling liquid, take care that the liquid does not drip
out of the tank and that the tank does not overflow.
When adding anticorrosion agents, antifreeze and other chemicals follow the
instructions of the manufacturer! By mixing various products poisonous and
aggressive chemicals can be created that can damage your health or the cooling
equipment of the machine.
2.9.

Machine functions check

Before you start the check study the chapter Machine control thoroughly. Do not
proceed with the check if you did not fully understand all control elements and
machine functions.
Check, if the machine or some parts of the machine were not damaged during
transport.
Check, if all covers are installed and functional. Check (with the Tenzomat) if the
saw band is correctly stretched. If it is necessary, you can stretch the saw band
according to chapter Selection and replacement of the saw band. Correct values of
the saw band tension are on the Tenzomat.
Switch on the main switch and check the motors and systems (saw band drive,
hydraulic pump, cooling pump, chips conveyor).
Open and close the main vice. Turn the saw frame of the band saw from one outer
position to the other outer position. Raise the saw frame to the top position and
than lower the saw frame to the lowest position.
Start the machine with the cooling pump and let it run without load until the
cooling system will be filled with cooling liquid. As soon as the cooling liquid starts
to escape from the nozzles of the cooling system, the cooling system is ready for
operation. Carry one cycle of cutting without material. Check, if the machine runs
with no irregularities. If all machine functions are run properly, the machine is ready