Electrical Connection; Check The Direction Of The Saw Band; Check The Correct Connection To The Electrical Network - Bomar Individual Automatic Series Operating Instructions Manual

Hide thumbs Also See for Individual Automatic Series:
Table of Contents

Advertisement

2.7.
2.7.1.
2.7.2.
24

Electrical connection

Attention!
Only a qualified professional must carry out the servicing
and repairs of the electric equipment! Take special care
during work with electrical equipment. High voltage shock can
have fatal consequences! Always keep notes about work safety.
Electrical parameters of the machine:
Service voltage:
Total input / Max. fuse:
Before connecting switch off the main switch of the power supply circuit for the
machine and ensure dry place when doing connecting works!
Service voltage must agree with the line voltage! Crosscut of the supply line must respond
with rated current for max. machine load.
Note:
The values of the crosscut of the conductor and the rated
current are in the norms.
Note:
The socket with the fork can be used only at the machines with
the rated current less than 16 A and total input less than 3 kW.
In case the machine is connected with a direct connection, an extra main switch must
be added which can be locked in zero position.
Attention!
In this case the extra main switch becomes primary and the
main switch on the machine has only secondary function.

Check the direction of the saw band

After the machine has been successfully connected, briefly switch on the machine and
put the driving engine of the band in the running position. The direction must be in
accordance with the arrow direction on the saw band cover. In case the direction of the
saw band does not match, two phases at the terminal strip must be switched.

Check the correct connection to the electrical network

Attention!
When you connect the machine to the electrical network
observe correct connection of all phases!
ENGINE IN IN HYDRAULIC AGGREGATE CANNOT BE
OPERATED WITH REVERSE TURNING MORE THEN 10
SECONDS!!!
~ 3×400 V, 50 Hz, TN-C-S
9,0 kW / 25 A
Manual version:
Manual rev.:
1.10 / Jan. 2011
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Individual 620.460 ganc

Table of Contents