Electrical Connection; Check The Direction Of The Saw Band; Filling Of The Cooling System - Bomar Practix Automatic Series Operating Instructions Manual

Table of Contents

Advertisement

2.8.
2.8.1.
2.9.
24

Electrical connection

Only a qualified professional must carry out the servicing
and repairs of the electric equipment! Take special care
during work with electrical equipment. High voltage shock can
have fatal consequences! Always keep notes about work safety!
Electrical parameters of the machine:
Service voltage:
~ 3×400 V, 50 Hz TN-C-S/TN-C nebo ~ 3×230 V/50 Hz TN-C
Total input / Max. fuse: 2 kW / 16 A
Before connecting switch off the main switch of the power supply circuit for the
machine and ensure dry place when doing connecting works!
Note:
The values of the crosscut of the conductor and the rated
current are in the norms.
Service voltage must agree with the line voltage! Crosscut of the supply line must respond
with rated current for max. machine load.
Note:
The socket with the fork can be used only at the machines with
the rated current less than 16 A and total input less than 3 kW
In case the machine is connected with a direct connection, an extra main switch must
be added which can be locked in zero position.
Attention! In this case the extra main switch becomes primary
and the main switch on the machine has only secondary
function.

Check the direction of the saw band

After the machine has been successfully connected, briefly switch on the machine and
put the driving engine of the band in the running position. The direction must be in
accordance with the arrow direction on the saw band cover. In case the direction of the
saw band does not match, two phases at the terminal strip must be switched.

Filling of the cooling system

Prepare the mixture of the water and the cooling liquid. Keep the concentration
specified by manufacturer.
Fill the mixture of the water and the cooling liquid to the tank of the cooling system.
Area of the tank for the cooling liquid is discovered from the chapter „Technical data".
Filling the tank with the cooling liquid, take care that the liquid does not drip out of the
tank and the tank does not overflowed.