Electrical Connection; Check The Direction Of The Saw Band - Bomar Ergonomic Series Operating Instructions Manual

Hide thumbs Also See for Ergonomic Series:
Table of Contents

Advertisement

2.7.
2.7.1.
40

Electrical connection

Attention!
Only a qualified professional must carry out the
servicing and repairs of the electric equipment! Take
special care during work with the electrical equipment.
High voltage accident can have fatal consequences! Always
follow instructions for work safety.
Electrical parameters of the machine:
Service voltage:
Total input
Max. fuse:
Before connecting the machine turn off the main power switch and ensure a dry
area for the connection work.
Note:
The values of the cross section of the conductor and the
rated current can be found in the regulations.
Service voltage must agree with the line voltage! Cross section of the supply line
must respond with the rated current for max. machine load.
Note:
The socket with the fork can be used only for machines with the rated
current less than 16 A and total input less than 3 kVA.
The input line is equipped with a 16 A socket for connection of the machine to the
electric supply line. In case the machine is connected with a direct connection, an
extra main switch which can be locked in zero position must be added.
Attention!
In this case the extra switch becomes the primary switch and the
main switch on the machine has only secondary function!

Check the direction of the saw band

After the machine has been successfully connected, switch on the machine and run
the driving engine of the band briefly. The movement of the band must be in
agreement with the direction of the arrow on the saw band cover. If the direction of
the saw band does not agree, the phases at the terminal line must be switched.
~ 3×400 V, 50 Hz, TN-C-S
1,7 kW
16 A
Manual version:
1.03/ May 2016
Manual rev.:
1