Activation

Machine working conditions

Keep the conditions of the manufacturer for machine operation! If the
recommendations are not kept, damage can occur to the machine.
The manufacturer warrants the correct function of the machine for these
conditions:
At air temperature from 10°C to 40°C; the temperature average during 24
hours must not exceed over 35°C.
At relative dampness of the air in the interval from 30% to 95% (not
condensing). Altitude up to 1000 meters.
Do not expose the machine to any radiation (microwave radiation, ultra-violet
radiation, laser radiation, x-ray radiation). Radiation can cause problems with
the machine function and deteriorate the condition of the insulation.

Band saw unpacking and assembling

1.
Remove the wrapping from the machine and unpack all parts.
Attention!
Switch off the main switch and lock it in position, before
you start the assembly! Otherwise, there is a possibility of
an accidental machine start.
2.
Now put all enclosed parts to place.

Installation of the length stop for the material length setting

1.
Slide the length stop into the hole on the side of the vice.