3.3.7.
58
Setting the type of cooling
The required type of cooling can be chosen using knob no. 3 o the control panel.
Cooling with liquid:
1.
The cooling pump runs, even if the pump is turned off (washing)
2.
The saw band runs without cooling.
3.
The cooling is turned on together with the saw band drive
Cooling with oil vapor- Microniser (optional equipment)
4.
Saw band runs without cooling.
5.
Cooling is turned on together with the saw band drive.
Manual version:
1.03/ May 2016
Manual rev.:
1