20 Standard value tables
Standard value table for machine
Travel
Item
Travel speed (idle running)
Travel speed (actual running)
Travel deviation
Machine drift on slope
Leakage from travel motor
20-10
Machine model
Measurement condition
For measuring
posture, see
"Travel 1"
Engine: High
idle
Hydraulic oil
temperature: 45
to 55 °C
Time required to
complete 5
turns after 1
turn with track
of one side
raised off
ground
For measuring
posture, see
"Travel 2"
Engine: High
idle
Hydraulic oil
temperature: 45
to 55 °C
Time required to
travel 20 m after
running up 10 m
For measuring posture, see
"Travel 2" and "Travel 3"
Engine: High idle
Hydraulic oil temperature: 45
to 55 °C
Travel deviation in travel of
20 m after running up 10 m
and more on level ground
Firm and level ground
For measuring posture, see
"Travel 4"
Stopping engine
Hydraulic oil temperature: 45
to 55 °C
Place machine on slope of
12deg. with sprocket on
uphill side.
Travel distance by machine
drift on slope for 5 minutes
Engine: High idle
Hydraulic oil temperature: 45
to 55 °C
Lock shoes and relieve travel
circuit
Standard value
Unit
for new machine
Lo
37± 4
sec.
Hi
22± 2
Lo
26 ± 2
sec.
Hi
14 ± 2
mm
Max. 200
mm
l/min
Max. 1.1
PC88MR-10
Repair limit
Max. 44
Max. 26
Max. 30
Max. 18
Max. 220
0
0
Max. 1.65
PC88MR-10