PC88MR-10
Procedure, measuring location, criteria and remarks
1. Turn starting switch to OFF position.
2. Insert T-adapter into connector J1.
3. Turn starting switch to ON position.
Voltage
Between J1 (15) and (59)
1. Turn starting switch to OFF position.
2. Insert T-adapter into connector J1.
3. Turn starting switch to ON position.
Between J1 (16) and (59) or
Voltage
between PAMB (3) and (2)
1. Turn starting switch to OFF position.
2. Insert T-adapter into connector PFUEL or J2
3. Turn starting switch to ON position.
Between PFUEL (2) and (3) or
Voltage
between J2 (21) and (44)
1. Turn starting switch to OFF position.
2. Insert T-adapter into connector J1 or CCV.
3. Turn starting switch to ON position.
Between J1 (3) and (59) or
Voltage
between CCV (3) and (2)
1. Turn starting switch to OFF position.
2. Disconnect connector FP, and connect T-adapter to male side.
Between FP (male) (A) and (C)
Between FP (male) (B) and (C)
Resistance
Between FP (male) (A) and (B)
1. Turn starting switch to OFF position.
2. Disconnect connector POIL , and connect T-adapter to male side.
Between POIL (male) (1) and ground
Resistance
(PC88MR-E000-033-P-00-A)
Procedure, measuring location, criteria and remarks
1. Turn starting switch to OFF position.
2. Disconnect connector V02, and connect T-adapter to male side.
Between V02 (male) (1) and (2)
Resistance
Between V02 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector V03, and connect T-adapter to male side.
Between V03 (male) (1) and (2)
Resistance
Between V03 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector V06, and connect T-adapter to male side.
Between V06 (male) (1) and (2)
Resistance
Between V06 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector V11, and connect T-adapter to male side.
Between V11 (male) (1) and (2)
Resistance
Between V11 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector V91, and connect T-adapter to male side.
Between V91 (male) (1) and (2)
Resistance
Between V921 (male) (1) and ground
1. Turn starting switch to OFF position.
2. Disconnect connector V92, and connect T-adapter to male side.
Between V92 (male) (1) and (2)
Resistance
20 Standard value tables
Standard value table for electrical system
Sensor output
Sensor output
Sensor output
Sensor output
0.3 to 4.7 V
0.3 to 4.7 V
0.2 to 4.6 V
0.3 to 4.7 V
4.0 to 6.0 kz
3 to 7 kz
3 to 7 kz
Max. 1 z
20 to 60 z
Min. 1 Mz
20 to 60 z
Min. 1 Mz
20 to 60 z
Min. 1 Mz
3 to 14 z
Min. 1 Mz
3 to 14 z
Min. 1 Mz
3 to 14 z
20-23