Type 2
(ALL-C930-925-P-02-A)
Disconnection
1. While holding the fitting, push body (7) in straight
until sliding prevention ring (6) hits contact
surface (a) at the hexagonal part on the male
side. (Fig. 6)
2. While keeping the condition of Step 1, turn lever
(8) to the right (clockwise). (Fig. 7)
3. While keeping the conditions of Steps 1 and 2,
pull out whole body (7) to disconnect it. (Fig. 8)
PC88MR-10
00 Index and foreword
Foreword, safety and general information
Connection
1. While holding the fitting, push body (7) in straight
until sliding prevention ring (6) hits contact
surface (a) at the hexagonal part on the male
side to connect it. (Fig. 9)
00-29